When your facility needs to process several different types of loads, the STERRAD® 200 System large-capacity sterilizer can make short work of fast-moving inventory demands.
For complete information about the parts, operation, routine maintenance, and technical details of the STERRAD® 200 System, please download the electronic Instructions for Use.
*The number of trays processed is based on a combination of the most commonly used APTIMAX® Trays times the number of loads completed within 16 hours. The EtO chamber size used for this calculation is 5.0ft3. The number of trays processed per load is subject to change depending upon tray sizes used.
Technical Specifications | ||||
Total cycle time | 75 minutes | |||
Cycle temperature | 115°F to 131°F (46°C to 55°C) | |||
Dimensions and Weight | ||||
Height | 69 in (1754 mm) | |||
Width | 36 in (915 mm) | |||
Depth | 44.5 in (1130 mm) | |||
Weight | 1047 lbs (475 kg) | |||
Sterlization Chamber | ||||
Configuration | Rectangular | |||
Usable volume | 5.3 ft3 (150 liters) | |||
Two-tiered shelf | 23.5 in x 23.5 in (597 mm x 597 mm) | |||
Installation and Electrical Requirements | ||||
Placement | In-wall or freestanding | |||
In-wall options | Single door or double door | |||
Freestanding | Single door | |||
Connections | 208 VAC / 60 Hz / 20A / 3 phase / 5 wire WYE / NEMA L21-20 receptacle | |||
Installation space | ||||
Minimum area | 36 in (W) x 44.5 in (D) (91.5 cm x 113 cm) | |||
Surface | Flat: +/- 5 mm/m | |||
Service requirements | 1000 mm service side, 450 mm non-service side; sides are selectable (39 x 18 inches); single-door unit can be moved for service |
|||
Operational Environment | ||||
Temperature | 64°F to 104°F / 18°C to 40°C | |||
Humidity | 10%-85% up to 30°C ambient and linearly decreasing from 85% at 30°C to 70% at 40°C | |||
Carriage Dimension (Optional Accessory) | ||||
Width | 30 in (762 mm) | |||
Depth | 49.5 in (1257 mm) | |||
Height | 35 in (889 mm) |
Regulatory approvals:
- CAN/CSA-C22.2 No. 1010.1-92; Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use
- UL 3101-1; Standard for Safety for Electrical Equipment for Laboratory Use
- EN 61010; Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use.
- EN 55011; Group II Class A limits, based on CISPR 11; Emissions
- FCC 47 Part 18: FCC Requirements for Industrial, Scientific, and Medical Equipment
- IEC 601-1-2; Medical Electrical Equipment, Collateral Standard, Electromagnetic Compatibility
- CE, a mark of conformity for the European Community
This link will take you to a Web site to which this Privacy Policy does not apply.
We encourage you to read the Privacy Policy of every Web site you visit.